For the most part, solar PV arrays are fairly simple and straightforward systems.
- Solar Panels (known in the industry as modules)
- Inverters (these invert the solar energy from DC into AC)
- Mounting System (the aluminium frame that anchors the solar modules to your roof)
Beautifully Simple
The beauty of solar PV compared to other forms of renewable energy, such as wind turbines for example, is that there are no moving parts.
This means that – providing the system was installed correctly in the first place – you are unlikely to have any sort of mechanical breakdown of the array.
That said, solar PV systems are like any other electrical installation; no matter what you do, things can and do go wrong.
The main point of failure in a solar installation is the inverter; the inverter is arguably the most important part of the whole array, and the part of the system that does the most work.
Common Solar Inverter Error Codes
Manufacturer: ABB / Fimer / Power One
E018 – Leak Fault – Leakage current fail
E021 – Internal Error
E025 – Riso Low – Insulation fault on Solar Array
E031 – Error Read V – Wrong V Measure
E034 – This is a common internal fatal error, an inverter with this error will usually start to cut out and then completely stop producing
E032 – This is the same as above but slightly less common
E502 – No production, could be for a variety of reasons including a faulty inverter
W003 – This is a common grid voltage error, a lot of the time it’s the grid’s fault but sometimes it can be the result of a faulty inverter
W010 – Fan Fault
Manufacturer: SMA
64xx – Interference device
3501 – Insulation resistance
1302 – Grid fault
Grid Incident 101 – This is similar to the ABB W003 error – it indicates a grid fault, potential grid voltage too high
Interference Device 6429 (And any error code between 6002-6412) – Faulty inverter, needs replacing or warranty claim with SMA
Low Riso – Insulation resistance
Manufacturer: Fronius
401 – Communication issue with power stage set
502 / 475 / 447 – Insulation resistance
509 – No production, could be for any reason including a trip
Manufacturer: Solis
OV-G-F / OV-G-V – Grid issues, or incorrect country code
Addressing Issues Quickly
If you do not have time to monitor the performance of your array yourself, why not place your system in one of BeBa’s maintenance portfolios? We are trusted by over 500 clients to proactively monitor their systems and react to any issues that present themselves. Moreover, if we cannot diagnose the fault remotely, our packages include free call outs so that you only need to pay for parts/labour not included in your maintenance agreement.